Galaxy installs ducted systems and ductless mini-splits for commercial and residential new construction, including ADUs. A ducted system delivers conditioned air through supply ducts and needs a planned return-air path. A ductless system uses indoor units connected to outdoor equipment, with refrigerant piping, electrical connections, and condensate drainage coordinated during installation. Neither arrangement should be selected on building size alone.
System type affects where equipment can be installed and how conditioned air reaches occupants. Rooftop units, commercial split systems, heat pumps, and variable refrigerant flow arrangements each have different equipment locations, connections, service needs, and control implications. Selection should account for the building’s plan, available utility infrastructure, operating pattern, maintainability, and the owner’s priorities. A system label by itself does not establish that a particular option is suitable for the site.
Duct routes should be reserved while structural members, ceilings, lights, fire protection, plumbing, and other services are being coordinated. Plan for duct dimensions, transitions, insulation where specified, access to dampers and service points, and the location of supply and return openings. A route that fits on a drawing may be obstructed by a beam or crowded above the finished ceiling. Resolving such conflicts before installation is easier than asking field crews to improvise after other trades have completed their work.
For ductless installation, establish where indoor units will deliver air to occupied rooms without blocked discharge or inaccessible service points. Plan outdoor unit clearances, refrigerant-piping routes, condensate drainage, and electrical provisions before finishes are complete. Multi-zone options should be reviewed against the actual room loads and control needs; a single indoor unit should not be presumed to condition every room behind closed doors.
Controls deserve the same attention as equipment. Identify which rooms or areas need independent control, where sensors and thermostats will be located, who can access them, and whether connection to a building automation system is intended. Zoning decisions influence duct design and operating behavior; sensors in an unrepresentative location can cause the system to respond poorly to occupied rooms. Confirm the intended control sequence and interfaces among the owner, design team, controls provider, and HVAC installer before procurement.